125mA medical diagnostic x-ray machine YSX0103
125mA medical diagnostic x-ray machine YSX0103
Unit Configuration
Control,HT generator unit,Ht cable,X-ray tube unit,Radiographic table-X-ray source column,Collimator
Function
The unit can used for general radiography, Bucky radiography of bodys head, chest, foot and hand, bones in lying.
Feature
1 meter-indicating.
2 single-table single tube.
3 single-phase, full wave rectification.
4 stationary anode x-ray tube assembly
5 X-ray tube filament s voltage regulator, space charge compensator
6 Radiograph plain table wimple structure and easy assembling
MIN TECHNICAL INDEXES
ITEM | CONTENTS | INDEX |
Demand of power supply | Capacity | Two-phase 30KVA |
Voltage Frequency | 380V/220V ±1050HZ ±0.5Hz | |
Intemal resistance | 2Ω(380V) 0.6 Ω(220V) | |
power supply | Adjustable range | 380±10% at220V being adjustable continuously |
Radiograph | Voltage | 50-90KV |
current | Small focus: 15mA,Big focus:30mA 60mA 100mA 125mA | |
time | 0.04~6.35s 23grades together grading a according to R10 coefficient | |
High-voltage generator | Capacity | 7KVA |
Max DC output voltage | 90KV | |
Max DC output current | 125mA | |
X-Ray tube | Model | XD4-2.9/100 |
Focus | Small focus 1.8×1.8mm big focus4.3×4.3mm | |
Radiographic table | Length*width*height of bed surface | 2000mm*665mm*700mm |
Moving range of bed surface | 640mm in Length | |
Ray-filter of table | Travel in length ≥50mm | |
Grid density N=28 | ||
Convergence distance f.=100cm | ||
r=8/Grid ratio r=8 | ||
Column of X-ray tube unit | Moving Longitudinally along Radiographic table | 1000mm or 1800mm |
Distance to friend as moving up and down (along column) | 650~1800mm | |
Rotary around the center of cross arm | ±180° | |
Rotary around the shaft line of X-ray annular tubes | -10°~60°~ +120° | |
Max size of cassette | 356mm×432mm(14×17) |