anesthesia medical machine YSAV0202
anesthesia medical machine YSAV0202
YSAV0202 Anesthesia Machine, designed with state-of-the-art technologies, is one of high utility with excellent performance and complete functions. Both outstanding and inexpensive, it has the best cost performance that can satisfy any customer.
1, The Ventilator adopts microcomputer control with high-definition 5.7” LCD display,integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.
2, The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
3, Reliable pneumatic transmission system.
4, Economic and proper configuration of technologies, optional as required by the Customer.
5, Modularized design and upgrading. Upgrading is available as required by the Customer.
Main body | High-strength engineering plastic rack, light, beautiful and corrosion resistant | ||
Scope of application | adult, child | ||
Gas source | O2: 0.27~0.55MPa N2O: 0.27~0.55MPa | ||
Flow meter | O2: 0.1~10L/min N2O: 0.1~10L/min | ||
O2, N2O linkage and N2O Stopper When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off. | |||
Flow rate of rapid oxygen supply | 25~75L/min | ||
Low oxygen pressure alarm | There will be sound alarm when the oxygen pressure < 0.2MPa | ||
Vaporizer | it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane, Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available. | ||
Respiratory circuit | working mode: all-close, semi-close, semi-open releasing pressure: 0.5~7 kPa | ||
Respiratory bellows | bellows for adults, bellows for children tidal volume range:0~1,500 ml | ||
Ventilator | |||
Display mode | High-definition 5.7” LCD screen display | ||
Ventilation mode | IPPV,SIPPV,SIMV,PEE,MANUAL,SIGH | ||
Ventilation parameters | Tidal volume | 50~1500ml | |
Rate | 2~99bmp | ||
SIMV rate | 2~20bpm | ||
I:E | 2:1~1:8 | ||
Inspiratory trigger pressure | -1.0~2.0 kPa | ||
PEEP | 0~2.0 kPa | ||
Pressure range | 1.0~6.0 kPa | ||
SIGH | 1.5 times the inspiratory time | ||
Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure | |||
Monitoring of oxygen concentration | (21%~100%) | ||
Security Alarm System | |||
Oxygen Concentration alarm | upper limit setting range (50%~100%) | ||
low limit setting range (15%~50%) | |||
Airway pressure alarm | upper limit setting range 1.0~6.0 kPa | ||
low limit setting range 0.4~2.0 kPa | |||
Per-minute ventilation volume alarm | upper limit setting range 3.0~30L/min | ||
low limit setting range 1.0~10L/min | |||
Sustained high-pressure alarm | it will give alarm when stress have consistently been higher than 2.5 kPa | ||
Suffocation alarm | it will give sound and light alarm if there is no tidal volume input for 15 seconds | ||
Power alarm | |||
Power | AC 220V±10% 50Hz±1Hz (UPS, Storage battery) | ||
Items within brackets are optional. |
anesthesia medical machine YSAV0202